The MYTOS family includes different solutions according to their installation environment:

Sensor Versions Measuring range/ Modules
in-line MYTOS & TWISTER 0.25 µm to 1,750 µm/ 5
on-line MYTOS & TWISTER 0.25 µm to 3,500 µm/ 6
on-line MYTOS & MIXER 0.25 µm to 1,750 µm/ 6
on-line MYTOS & SCREWSAMPLER 0.25 µm to 1,750 µm/ 5
on-line MYTOS & Probes 0.25 µm to 3,500 µm/ 6
at-line MYTOS & VIBRI 0.25 µm to 3,500 µm/ 7
at-line MYTOS & VIBRI Module 0.25 µm to 1,750 µm/ 5
off-line MYTOS & VIBRI Module 0.25 µm to 1,750 µm/ 5
  • Efficient dry dispersion ensuring complete dispersion for fine, even cohesive powders down to the submicron range with MYTOS
  • Real-time particle size analysis with laser diffraction of perfectly dispersed powders with up to 2,000 measurements per second
  • Representative sampling in or out of process pipes in the diameter range from 38 to 660 mm at product temperatures of up to 150°C with TWISTER
  • Comparability to the established off-line laser diffraction system HELOS | RODOS that share the same core components for a valid method transfer
  • Connection to process control systems | TCP/IP, OPC, Modbus®, Profibus®, PLC signals

Download more information about MYTOS & Co.

Forgot your password?

Please enter your username or email address. Instructions for resetting the password will be immediately emailed to you.

Reset Password

Return to login form

Configuration
MYTOS + TWISTER in-line

MYTOS + TWISTER in-line

boost: 4

Laser Diffraction | Dry
Size range: 0.25 µm - 1,750 µm
Mass flow rate: 1 kg/h - 100+ t/h

Show configuration

Suited for

Applied for control of

The laser diffraction sensor MYTOS forms together with the representative sampler TWISTER a closed, perfectly coordinated and robust in-line process analysis system, which is directly integrated in the process line.

The laser diffraction sensors MYTOS form together with representative samplers like TWISTER, MIXER, SCREWSAMPLER and probes perfectly coordinated and robust on-line process analysis systems. The sampler is integrated in the process line, takes a sample and feeds it directly to the particle size analysis.

Configurations
MYTOS + TWISTER on-line

MYTOS + TWISTER on-line

boost: 7

Laser Diffraction | Dry
Size range: 0.25 µm - 3,500 µm
Mass flow rate: 1 kg/h - 100+ t/h

Show configuration

Suited for

Typical applications

Applied for control of

MYTOS + MIXER

MYTOS + MIXER

boost: 5

Laser Diffraction | Dry
Size range: 0.25 µm - 3,500 µm
Mass flow rate: 1 kg/h - 400 kg/h

Show configuration

Suited for

Typical applications

Applied for control of

MYTOS + Probe

MYTOS + Probe

boost: 6

Laser Diffraction | Dry
Size range: 0.25 µm - 3,500 µm
Mass flow rate: 1 kg/h- 3 t/h

Show configuration

Suited for

Typical applications

Applied for control of

MYTOS + SCREWSAMPLER

MYTOS + SCREWSAMPLER

boost: 5

Laser Diffraction | Dry
Size range: 0.25 µm - 1,750 µm
Mass flow rate: 1 kg/h - 1 t/h

Show configuration

Suited for

Typical applications

Applied for control of

The at-line versions of the robust dispersion and sensor units MYTOS combined with the dosing unit VIBRI are suitable for automated laboratory operations. The integration in the central control system and the reporting of results are adapted to the existing communication environment. The system is either mounted stationary to a wall or frame or in a mobile rack.

Configurations
MYTOS + VIBRI

MYTOS + VIBRI

boost: 4

Laser Diffraction | Dry
Size range: 0.25 µm - 3,500 µm
Sample amount: < 1 mg - 1,000 g

Show configuration

Suited for

Typical applications

Applied for control of

MYTOS + VIBRI Module

MYTOS + VIBRI Module

boost: 1

Laser Diffraction | Dry
Size range: 0.25 µm - 1,750 µm
Sample amount: < 1 mg - 1,000 g

Show configuration

Suited for

Typical applications

Applied for control of

The laser diffraction sensors MYTOS  can also be used as a manually operated laboratory instruments. As standard, the systems are pre-equipped for potential integration at a later date into a fully-automated at-line laboratory automation system.

Configurations
MYTOS + VIBRI

MYTOS + VIBRI

boost: 4

Laser Diffraction | Dry
Size range: 0.25 µm - 3,500 µm
Sample amount: < 1 mg - 1,000 g

Show configuration

Suited for

Typical applications

Applied for control of

MYTOS + VIBRI Module

MYTOS + VIBRI Module

boost: 1

Laser Diffraction | Dry
Size range: 0.25 µm - 1,750 µm
Sample amount: < 1 mg - 1,000 g

Show configuration

Suited for

Typical applications

Applied for control of

Laser diffraction analyser HELOS/BR with dry and wet dispersion OASIS/L and dosing unit VIBRI/L for the determination of particle size distribution.

The proven HELOS series – with its classical laser diffraction set-up deploying a parallel beam – offers a powerful technology for particle size analysis of powders, granules, suspensions, emulsions, sprays and numerous other disperse systems from below 0.1 µm to 8,750 µm. A great variety of dispersing and dosing units provides a flexible adaptation to myriads of industrial and research applications.